1300 556 601
Login
IPD Group
Search
Products
Circuit Breakers & Load Centres
DIN MCB
Moulded Case Circuit Breakers
Air Circuit Breakers
Load Centres
Chassis Systems
DIN Accessories
Isolators & Switches
Load Break Switches
Switch Disconnectors
Changeover Switches
Bypass Switches
Transfer Switches
Distribution Boards
Evolution Distribution Boards
T Series Distribution Boards
Cable Tee-Off Boxes
Assembled Distribution Boards
Switchboard Safety
ARC Monitor
ARC Protection Equipment
Fuses & Fittings
Industrial Fuse Links
Fuse Fittings
Power Supplies & Transformers
Uninterruptible Power Supplies (UPS)
Transformers
Power Supply Redundancy Modules
Industrial Power Supplies
Energy Management
Power & Multifunction Meters
Energy Management Solutions
Current Transformers
Power Quality
Lightning & Surge Protection
Power Factor Correction & Quality
Enclosures
Techno Modular Switchboards
Plastic Enclosures
Metal Enclosures & Accessories
Climate Control
Filter Fans & Thermal Control
Cooling Units
Automation Systems
Programmable Logic Controllers & I/O
HMI Panels
Industrial Computers
Automation Software
Process Meters & Controllers
Control Devices
Electrical Time Switches, Timers & Control Relays
Relays
Position Switches & Sensors
Pilot & Signalling Devices
Signal Conditioners
Pressure Sensors
Level Sensors
Motor Control & Protection
Contactors
Safety Contactors
Soft Starters
Motor Protection & Motor Starters
Variable Speed Drives
Motors
Security & Remote Access
Security Devices
Remote Access
Media & Protocol Converters
Device Servers
Protocol Converters
Ethernet Switches
Modems & Routers
Industrial Wi-Fi
Patch Panels
Cables & Accessories
Safety Automation & Control
Safety Interlocks
Presence Sensing Safety Devices
Safety Relays & Controllers
Safety Pushbuttons & Operator Devices
Hazardous Area Equipment
Hazardous Area Terminal Boxes
Hazardous Area Control Boxes
Hazardous Area Lighting
Hazardous Area Plugs & Sockets
Hazardous Area Intrinsically Safe Isolators
Hazardous Area Cameras
EV Solutions
EV Charger Wall Boxes
EV Solutions
PV Solutions
Photovoltaic Isolators & Protection
Photovoltaic Assemblies
Switchgear 1500VDC
Weatherproof Switchgear
W66 Industrial IP66 Switchgear
EU67 Industrial IP67 Switchgear
Outdoor Isolators & Socket Outlets
Cable Cleats & Clamps
Polymeric Cable Cleats
Wiring Terminals & Ducts
Standard Feed Through Terminal Blocks
Earth Terminal Blocks
Disconnect & Test Terminal Blocks
Double & Triple Level Terminal Blocks
Fuse Terminal Blocks
Spring Loaded & Clamp Terminal Blocks
Power & Other Terminal Blocks
Melamine Terminal Blocks
Installation Accessories
Wiring Accessories
Enclosed Links
Aluminium Terminal Blocks
LV Joints, Compound & Resin
Cable Pulling Lubricants
Hardware
Electrical Tapes
Cable Laying
Illumination Units
Featured Products
Resources
Brochures & Catalogues
CAD Blocks
Software
Training
Automation Training
Industrial Communication
Insights
About
Contact
Following is a list of articles. Click the 'View' button to see the detail of the article.
Return to Article List
Fieldbus communication reduces wiring costs when compared to traditional hardwired input/output connections. FENA-21 is an optional fieldbus adapter module available for
ABB drives
that provide an interface to Modbus/TCP, EtherNet/IP, or PROFINET IO. Through the fieldbus adapter module, you can give control commands, transfer process data to and from the drive, read actual values and drive status or reset a drive fault.
This ‘Tech Tip’ is to help set up an ABB drive for fieldbus control with the FENA-21
. As an example, we will show you how to set up a FENA-21 on ABB’s ACS580 drive and configure frequency control using Modus/TCP.
FENA-21 comes standard with your drive if it features a plus code of +K475 and is enabled inside the drive parameters. However, if the drive is not factory equipped with the module and you want to add the fieldbus adapter later on, you need to enable the communication between the drive and the fieldbus adapter module with parameter
50.01 FBA A enabled.
This is done after installing the adapter and powering up the drive. Each ABB drive has a specific option slot for the adapter module. The selection must correspond to the slot where the adapter module is installed. For example, if the adapter module is installed in slot 1, you must select slot 1.
50.01 FBA A enable 1 = Option slot 1
You can select how the drive should react to a fieldbus communication break with
50.02 FBA A comm loss func.
No action will be taken as default. But if a function is set for this parameter (i.e. fault), then you can define the time between communication break detection and the selected action with
50.03 FBA A comm loss t out
. The default time out is set at 0.3 sec.
50.02 FBA A comm loss func: 1 = Fault
50.03 FBA A comm loss t out: 3.0 s
You can select application-specific values for the rest of the parameters in group
50 Fieldbus adapter (FBA),
starting from 50.04. In this example we configure operation type and scaling to be chosen automatically according to the current active operation mode in Parameter 19.01
50.04 FBA A ref1 type: 0 = Speed or frequency
Fieldbus adapter module configuration parameters needs to be configured in group
51 FBA A settings.
As a minimum, you will need to set the required node address and the communication profile. In this example we are using the Modbus/TCP protocol and the ABB Drives - Enhanced profile. The IP address is set to 192.168.0.16 and network mask as 255.255.255.0
51.01 FBA A type: 128 = ETHERNET
51.02 Protocol/Profile 1 = MB/TCP ABB E
51.04 IP configuration: 0 = Static IP
51.05 IP address 1: 192
51.06 IP address 2: 168
51.07 IP address 3: 0
51.08 IP address 4: 16
51.09 Subnet CIDR: 24
The process data transferred to and from the drive, needs to be defined in parameter groups
52 FBA A data in
and
53 FBA A data out
. Note that depending on the communication protocol and profile being used, the Control word and Status word may already be configured to be sent/received by the communication system.
52.01 FBA A data in1: 01.14 (Output power)
52.03 FBA A data in3: 01.11 (DC voltage)
53.01 FBA A data out1: 28.26 (Constant frequency 1)
53.03 FBA A data out3: 28.27 (Constant frequency 2)
Save the valid parameter values to permanent memory by setting parameter
96.07 Parameter save manually
to
Save
. This ensures that operation can continue after cycling the power.
Validate the FENA-21 configuration parameters by setting parameter
51.27 FBA A par refresh
to Configure. After refreshing, the value reverts automatically to Done.
Configure control location EXT1 to allow control and reference signals to come from the fieldbus. In this example we are selecting the fieldbus interface as the source of the start and stop commands, speed reference, and fault reset. The start/stop commands and reference are according to the ABB Drives profile.
20.01 Ext1 commands: 12 = Fieldbus A
22.11 Speed ref1 source: 4 = FB A ref1 Selects
31.11 Fault reset selection: 06.1.7
After the adapter module has been initialised by the drive, you must prepare the client for communication with the module.
For any additional information, we recommend you check out the below link to the FENA-21 user’s manual PDF:
https://library.e.abb.com/public/d6a31af1808043ba8ef53980031041ea/EN_FENA01_11_21_UM_E_A4.pdf