Products

ABB PSE142-600-70 Softstarter 143A 208-600VAC IP00

Product Code: PSE142-600-70

  • Supports 208-600 VAC, 143 A, and 50/60 Hz
  • Features Modbus RTU communication
  • Offers soft start/stop with torque control
  • Integrated electronic overload protection
  • Compact design: 130mm W x 295mm H x 220mm D
In Stock Low Stock Out Of Stock Please See Attributes

Specifications

Product Type Softstarter
Brand ABB
Actuating Voltage Type AC
Ambient Temperature -40 to 70 deg C
Analogue Outputs 4-20 mA
Circuit Voltage 24 VDC
Colour Green
Communication Modbus RTU
Connecting Capacity 1/2 x 2.5-70 sq-mm Rigid
Degree of Protection IP00
Depth 220 mm
Fault Signal Relay Yes
Function Soft Start with Torque Control, Soft Start With Voltage Ramp, Soft Stop With Torque Control, Soft Stop With Voltage Ramp, Kick Start, Sequence Start, Current Limit, Start Reverse (External Contactors), Automatic Restart, Event Log
Height 295 mm
HP Rating 40 hp, 50 hp, 100 hp, 125 hp
Integrated Electronic Overload Yes
Number of Starts Per Hour 10
Operational Temperature -25 to 60 deg C
Overload Protection Yes
Overload Signal Relay Yes
Rated Current 143 A
Rated Frequency 50/60 Hz
Rated Power 40 kW, 75 kW, 90 kW
Rated Voltage 208-600 VAC
Release Class Adjustable
Service Factor 100%
Terminal Type Bar
Tightening Torque 0.5 N-m Control Circuit, 18 N-m Main Circuit, 0.5 N-m Supply Circuit
Weight 4.4 kg
Width 130 mm

Description

<p>The General - PSE is a robust and versatile solution for industrial and commercial applications, designed to meet the rigorous demands of various operations. With its rated voltage ranging from 208-600 VAC and a current capacity of 143 A, this product offers flexibility across different power systems. It operates efficiently at both 50 and 60 Hz frequencies, ensuring compatibility with global standards.</p><p>Its connecting capacity accommodates between 2.5 to 70 sq-mm rigid cables, making it adaptable to various installation requirements. The Modbus RTU communication capability provides seamless integration into existing systems for efficient monitoring and control. This feature is particularly beneficial for facilities aiming to enhance automation and data acquisition processes.</p><p>With a bar terminal type, the General - PSE ensures secure connections that are crucial for maintaining operational reliability. The specified tightening torque values—0.5 N-m for the control circuit, 18 N-m for the main circuit, and 0.5 N-m for the supply circuit—are essential details that help in achieving optimal setup conditions.</p><p>Despite its IP00 degree of protection indicating no enclosure against dust or water ingress, this product finds its niche in controlled environments where such factors are not a concern. Its compact dimensions (130 mm width x 295 mm height x 220 mm depth) allow it to fit comfortably within standard panel configurations while weighing just 4.4 kg.</p><p>The General - PSE excels in temperature resilience with an operational range from -25&amp;#176;C to +60&amp;#176;C and can withstand ambient temperatures as low as -40&amp;#176;C up to +70&amp;#176;C without compromising performance integrity.</p><p>Rated power options include 40 kW, 75 kW, and up to an impressive 90 kW capability, paired with HP ratings of up to 125 hp catering to diverse application needs from moderate duty motors up through more demanding tasks requiring higher horsepower output.</p><p>Functionally rich features like soft start with torque control or voltage ramping ensure smooth motor operation during startup phases while minimizing mechanical stress on equipment components—a key factor in extending machinery lifespan. Soft stop functions mirror these benefits during shutdown sequences by reducing abrupt halts that could otherwise lead to wear over time.</p><p>Additional functionalities such as kick start boost initial torque when needed; sequence start coordinates multiple motor activations; current limit protects against excessive draw; start reverse via external contactors adds versatility; automatic restart enhances uptime post-outages; event logs facilitate troubleshooting by recording operational history.</p><p>Integrated electronic overload protection alongside analogue outputs (4-20 mA) further bolsters system safety measures while providing real-time feedback on performance metrics critical for ongoing maintenance strategies.</p><p>Incorporating overload signal relay confirms readiness against potential overcurrent scenarios whereas fault signal relay alerts operators promptly upon detecting irregularities ensuring swift corrective actions can be taken—vital aspects contributing towards maintaining high service factors consistently at full capacity usage levels throughout deployment cycles.</p>