ABB E42H3ETG40W Automatic ACB 1600-4000A 3-P 100kA Withdrawable E4.2 Ekip Touch LSIG

Product Code: E42H3ETG40W

  • Automatic ACB with 1600-4000 A capacity
  • High breaking capacity of 100 kA
  • Ekip Touch LSIG trip unit for precise control
  • Rated impulse withstand voltage at 12 kV
  • Complies with IEC 309 standards
In Stock Low Stock Out Of Stock Please See Attributes

Specifications

Product Type Automatic Air Circuit Breaker
Brand ABB
Breaking Capacity 100 kA
Component Type Withdrawable
Frame Size E4.2
Number of Poles 3
Power Loss 900 W
Rated Current 1600-4000 A
Rated Impulse Withstand Voltage 12 kV
Rated Insulation Voltage 1000 VAC
Rated Short Time Withstand Current 85 kA
Rated Voltage 690 VAC
Standards and Approvals IEC 309
Terminal Type Horizontal Rear Spread
Trip Unit Ekip Touch LSIG
Version Withdrawable

Description

<p>When selecting an Automatic Air Circuit Breaker (ACB) for your industrial or commercial application, it’s essential to ensure that the product aligns with your specific technical requirements. This ACB, with its robust specifications, offers a reliable solution for managing electrical systems in demanding environments.</p><p>The rated current of this ACB ranges from 1600 to 4000 amps, making it suitable for a variety of applications where high current capacity is needed. Its ability to handle a rated impulse withstand voltage of 12 kV and a rated insulation voltage of 1000 VAC ensures it can operate effectively under challenging conditions, providing safety and reliability.</p><p>One of the standout features is its rated short-time withstand current capability of 85 kA. This means the breaker can handle high fault currents without damage over short periods, ensuring continued protection and operational integrity. Additionally, with a breaking capacity of up to 100 kA, this ACB is designed to interrupt fault currents efficiently and safely.</p><p>The Ekip Touch LSIG trip unit integrated into this breaker provides advanced protection features including long-time (L), short-time (S), instantaneous (I), and ground fault (G) protections. This comprehensive protection scheme helps in minimizing downtime by quickly responding to faults within the system.</p><p>This model includes three poles and fits within an E4.2 frame size, which should be considered when planning installation space. The terminal type is horizontal rear spread, allowing flexibility in mounting options depending on your setup requirements.</p><p>In terms of efficiency considerations, this ACB has a power loss rating of 900 watts. While power loss is inherent in all circuit breakers due to their operation principles, understanding these losses helps you manage overall system efficiency better.</p><p>Compliance with IEC 309 standards further assures users that this product meets international safety and performance benchmarks required for industrial applications.</p><p>Overall, if you&amp;#39;re looking for an Automatic ACB that combines robust performance with advanced protection capabilities under stringent standards compliance, this model stands out as a strong contender worth considering for your electrical infrastructure needs.</p>